The Bioprocessor construction is connected to a voltage of 220 V at 50 Hz, which is dangerous for human life.
All work related to the connection to the power grid, preventive maintenance, and repair measures must be done by qualified specialists who are authorized to perform the work in accordance with the applicable regional regulations.
The Bioprocessor unit is connected with a separate 3x1.5 PVA cable through a voltage regulator and protected by a single-pole circuit breaker with a cut-off current of 4A. The cable must be laid underground in a protective sheath in accordance with the Electrical Installation Regulations.
When choosing how to release treated wastewater, the type of soil and the depth of groundwater are considered.
If the soil has a high filtration coefficient (sand or sandy loam), the wastewater treated by the Bioprocessor unit is discharged into the drainage system.
The Bioprocessor plant uses exclusively biological methods for wastewater treatment, therefore, the ingress of objects and substances that are not processed by this method or harm the biocenosis of activated sludge into the sewer system negatively affects the operation of the system and the treatment process.
For the sustainable operation of the plant and to prevent emergencies (destruction of activated sludge, blockage of pumps), it is strongly recommended not to discharge into the sewerage system: